Products

  • CT-5711: Bus extended master module

    CT-5711: Bus extended master module

    CT-5711 Bus extended master module

    Module Description

    The bus extened master module is used to extend the bus.The bus extended master module has no process data and configuration parameters.

     

  • CT-5721: Bus extended slave module

    CT-5721: Bus extended slave module

    CT-5721 Bus extended slave module

    The bus extened slave module is used to extend the bus.The bus extended slave module has no process data and configuration parameters.

  • ODOT CN-8012: Profibus-DP Bus Adapter

    ODOT CN-8012: Profibus-DP Bus Adapter

    CN-8012 Profibus-DP Bus Adapter

    Module Overview

    CN-8012 PROFIBUS-DP network adapter supports access of standard PROFIBUS-DP, and the protocol version it supports is DPV0.

  • ODOT CN-8011: Modbus-RTU Bus Adapter

    ODOT CN-8011: Modbus-RTU Bus Adapter

    CN-8011 Modbus-RTU Bus Adapter

    Module Overview

    CN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication, it supports function code of 01/02/03/04/05/06/15/16/23, and this device could monitor the IO module communication state in real time.

  • ODOT CN-8021:CANopen Bus Adapter

    ODOT CN-8021:CANopen Bus Adapter

    CANopen is an open and flexible high-level protocol with more and more applications.
    Based on the CAN bus, it combines low cost and high performance, and provides an attractive distributed control solution for industrial automation, medical devices, public transportation, elevators, maritime electronics, and other applications.

  • CT-5801: Terminal module

    CT-5801: Terminal module

    CT-5801: Terminal module
    Terminal modules are used to stabilize the internal bus communication.

    Each C series I/O protocol adapter must be equipped with 1pc of terminal module CT-5801 no matter how many sub-modules are connected.

    The dustproof terminal could cover the internal bus and field power supply hardware of the last IO module.

    And terminal modules have no process data and configuration parameters.

    * Take no module channel and replace CT-5800.

  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll or Non-standard protocol to ProfiNet Converter

    ODOT-PNM02 V2.1

    Modbus (master/slave, RTU/ASCII) to ProfiNET, 2 port serial port (RS485/ RS232 / RS422), supports 50 slots, 200 commands in TIA portal (by configured software), support MAX 60 slaves

    ♦ Supports protocol conversion between Modbus and PROFINET

    ♦ Supports 2* RS485/RS232 or 1*RS422

    ♦ Supports Modbus master or slave, and supports RTU or ASCII

    ♦ Supports working temperature of -40〜85°C

    ♦ Supports data area: 2 serial Modbus-RTU/ASCII to PROFIBUS gateway with Max. input 1440 bytesand Max. output 1440 bytes

    ♦ Supports one key reset

    ♦ ODOT-PNM02 V2.0 supports Maximum slots: 50

    ♦ ODOT-PNM02 V2.1 supports 60 slaves (200 read and write commands)

  • CP-9131

    CP-9131

    CP-9131 is the first version of ODOT Automation PLC, the programming environment follows the IEC61131-3 international standard programmable system, and it supports 5 programming languages such as Instruction List (IL), Ladder Diagram (LD), Structured Text (ST), Function Block Diagram (CFC/FBD) and Sequential Function Chart (SFC).

    The PLC could support 32 pcs of IO modules, and its program storage supports 127Kbyte, data storage supports 52Kbyte, the data storage area contains input area of 1K(1024Byte), output area of 1K(1024Byte), and intermediate variable area of 50K.

    With built-in standard serial communication RS485 interface, it carries with 2 RJ45 interfaces which is a small PLC with rich functions.

    CP-9131 is the core component of the whole C series, its main work is not only responsible for executing the user’s logic program, but also responsible for all I/O data receiving and sending, communication data processing and other works.  With rich instructions, reliable function, good adaptability, compact structure, easy to expand, cost-effective, strong versatility, programming, monitoring, debugging, field operation are very convenient, the PLC could be applied to a variety of automation systems.

    The Ethernet interface on the CPU supports the Modbus TCP Server function, supports the third-party Modbus TCP Client to accesss data, supports Modbus TCP Client function, supports to access to data of third-party Modbus TCP Server.

    The RS485 port supports the Modbus RTU master, Modbus RTU slave, and supports third-party devices to communicate with PLC through a serial port.

  • B32 Series Modular integrated IO

    B32 Series Modular integrated IO

    ODOT B series integrated I/O module

    ODOT B series integrated I/O module consists of communication board (COMM board) module and extended IO module. The COMM board could select the corresponding bus module according to the communication interface of the controller system. The mainstream industrial communication protocols include Modbus, Profibus-DP, Profinet, EtherCAT, EtherNet/IP, CANopen, CC-Link, PowerLink, etc. The extended I/O module is divided into six categories: digital input module, digital output module, analog input module, analog output module, special module, and hybrid I/O module.

    The COMM board and extended IO modules could be freely combined based on site requirements. The integrated IO module could lower the cost when there are few data points.

  • ODOT-S1E1 V2.0: Serial Gateway

    ODOT-S1E1 V2.0: Serial Gateway

    This is a converter developed by Sichuan Odot Automation System Co., LTD between RS232/485/422 and TCP/UDP.This protocol converter can easily connect serial port devices to Ethernet and realize network upgrade of serial port devices.

    Protocol converter supports the function of “data transmission”, which can be set as a client or a server. This function can easily realize the data communication between PLC, server and other Ethernet devices and the underlying serial port devices.

    Supports TCP server and TCP client transparent transmission
    Supports UDP transparent transmission and virtual serial ports
    Supports transparent transmission with or without protocol. Protocol transparent transmission supports MODBUS RTU/ASCII
    Supports WEB browser configuration parameters (Common parameters) Serial port baud rate 1200 to 115200 bps

  • ODOT-MS100T/100G Series : 5/8/16 Port Unmanaged EtherNet Switch

    ODOT-MS100T/100G Series : 5/8/16 Port Unmanaged EtherNet Switch

    MS100T

    10/100 Mbps self-adaption,(Auto-MDI/MDI-X)

    Supports IEEE 802.3 for 10BaseT

    Supports IEEE 802.3u for 100BaseT and 100BaseFX

    Supports IEEE 802.3xfor flow control

    Supports broadcast storm protection

    Supports working temperature: -40~85℃

    5/8/16 ports unmanaged Ethernet Switches DIN-rail

  • MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX CANopen to Modbus TCP converter

    MG-CANEX Protocol Converter

    CANopen to Modbus TCP protocol converter

    MG-CANEX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.

    As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.

12345 Next > >> Page 1 / 5